ACXA73C76070 Panasonic IC Board [ CS-XPU18XKH-1 ]
Specifications
Details
Panasonic Air Conditioner Parts
Indoor Parts
ACXA73C76070 Electronic Controller - Main
CS-XPU18XKH-1
** Ready Stock **
Any question feel free to contact us .
( Kami membekalkan semua bahagian untuk penghawa dingin Panasonic. )
We deliver to all states in Malaysia .
H11 error code
Indoor / Outdoor Abnormal Communication
1. Faulty outdoor unit PCB .
2. Faulty indoor unit PCB .
3. Indoor-outdoor singnal transmission error due to wrong wiring .
4. Indoor-outdoor singnal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units .
5. Indoor-outdoor singnal transmission error due to disturbed power supply waveform .
.png)
H12 error code
Indoor / Outdoor Capacity Rank Mismatched
- Wrong models interconnected .
- Wrong indoor unit and outdoor unit PCBs used .
- Indoor unit or outdoor unit PCB defective .
- Indoor-outdoor singnal transmission error due to wrong wiring .
- Indoor-outdoor signal transmission error due to breaking of wire3 in the connection wires between the indoor and outdoor units.
.png)